TOC Sensor
Working principle
This instrument adopts the principle of ultraviolet catalytic oxidation, to oxidize the organic matter in the sample into carbon dioxide, where the test of carbon dioxide test uses the direct conductivity method, to determine the total organic carbon content through the test of the difference between the total carbon content in the sample after oxidation reaction and the total inorganic carbon content in the sample without oxidation, i.e., the total organic carbon (TOC) = total carbon (TC) - total inorganic carbon (TIC).

1.The rotating quartz glass tube coated with titanium dioxide; 2. UV lamp; 3. Conductivity sensor; 4. Delay coil; 5. Peristaltic pump
Parameters:
|
Power Supply |
100 – 260 VAC, 50HZ, 120W |
|
Conductivity Detection Range |
0.055us/cm-8.000us/cm |
|
Measure Range |
0.001mg/L~1.0 mg/L(1~1000ppb) |
|
Accuracy |
±3% |
|
Resolution |
0.001mg/L |
|
Analyzing Time |
Continues Analyzing |
|
Response Time |
5mins |
|
Measuring Limit |
0.001 mg/L |
|
Sample Temperature |
1-99℃ |
|
Applied Range |
Offline in the Laboratory,Cleaning Validation |
|
Authority Management |
User name and password login ,to meet FDA 21CFR PART 11 requirements |
|
Print Function |
External Printer |
|
Historical Records |
More then 5000 sets |
|
Audit trail |
customized |
|
Audit trail records |
≥3years |
|
Display Screen |
Color Touch Screen |
|
Weight |
8.5KG |
|
Dimension(mm) |
400*240*270 |
Features
◆ No need of nitrogen, oxygen, acid reagent and oxidant, so the operation is simple and the cost is low;
◆ Can be used in off-line laboratory, to meet the test and cleaning validation for organic carbon injection water and purified water;
◆ Equipped with automatic sampler, and the system suitability validation can be done automatically;
◆ It has the limit alarm design, and when the test sample exceeds the prescribed limit, the instrument makes automatic alarm;
◆ It is in conformity with the test scheme as specified in the new edition of state pharmacopoeia;
◆ Automatic lock screen in time 0-60mins, set "0" is unlock screen mode;
◆ Users quantity can add to 100 ;
◆ If the user's password is entered incorrectly for 5 times, the system will automatically freeze the user. After freezing, the system level user can change the password to unlock. When changing the password, it is necessary to change the locking state to the active state.
◆ Add user running valid date is 1-999 days
◆ When the user state is locked, the system level user can be unlocked, but the password is changed at the same time, the original password can not be used
◆ When connecting automatic sampler test or single machine offline test, it is necessary to enter the sample name, and you can enter numbers, letters, symbols, 0 ~ 16 digits.
Detail :

Application
Laboratory testing of pharmaceutical water (purified water, injection water), and cleaning validation, electronic industry, food industry, etc.