The Method of Pressure Decay

Jul 26, 2022 Leave a message

The Method of Pressure Decay

The method of pressure decay also is called pressure decay test. During the test procedure, using a high accuracy gauges and high precision pressure sensor monitor the upstream in that air leaking or across the filter will cause gas diffusion leading to pressure change. The test has two primary purposes:

1. To measure the tightness of filter system;

2. To test the integrity of filter.

The earlier version of the machine has not yet adopt the apparatus and program. That is exclusively used in test the upside volume. It can’t achieve the function of precisely measuring the upside volume in real time. Therefore, it can’t figure out the value of diffusion flow.

Generally, the method of measuring pressure decay of filter can be roughly regarded as the method of measuring diffusion flow. After a moment, measuring its attenuation value can be judged as the integrity of filter. 

However, owing to the limitations of basic theory, sensor hardware, removing the functions of temperature compensation and volume calibration compensation, the reliability and sensitivity of test data have a considerable loss.


Send Inquiry

whatsapp

Phone

E-mail

Inquiry